Please sign in to check inventory.
The Opto-Engineering TCEL066 delivers the advantages of a telecentric lens, with the flexibility of a liquid lens.
The Opto Engineering TCEL series combine telecentric optics with an Optotune liquid lens. This combination greatly increases the effective depth of field. You can use free software to manually adjust the focus as needed, making an object feature clear and sharp. Or, deploy focus stacking software (sold separately) to build a composite image with all features in focus.
Small changes in focus take just a few milliseconds. There are no motors or complicated gear mechanisms to wear out.
The Optotune liquid lens controller (sold separately) features a USB interface. A serial protocol enables communication with most software development tools.
Due to the integrated liquid lens, magnification varies with the working distance.
Loading...
Current Range: | -500 to +500 mA |
Temperature Sensor: | Yes, for focal power mode |
Lens Mount: | C-Mount |
Length: | 149.3 mm |
Filter Thread: | None (slip-on filters avaiable) |
Lens Type: | Telecentric |
Magnification: | 0.670 |
Distortion: | < 0.20 % |
Depth of Field: | 1.40 mm |
Working Distance: | 146.1 - 112.3 mm |
F#: | 12.0 |
Image Circle: | 11.00 mm (2/3") |
Telecentricity: | 0.04° typical, 0.08° max. @ 0 dpt; 0.15° @ -2 to +3 dpt |
Resolution: | 11 μm (object side, calculated with the Rayleigh criterion with λ= 520 nm) |
Storage Temperature: | 0 to 50°C |
Operating Temperature: | 0 to 40°C |
Operating Relative Humidity: | 20 to 85%, non-condensing |
Liquid Lens Model: | Optotune EL-16-40 |
Lifecycles: | > 1,000,000,000 (10 to 90% sinusoidal) |
Response time: | 5 ms typical at 30°C, 0 to ±250 mA step |
Setting time: | 25 ms typical at 30°C, 0 to ±250 mA step |
Repeatability: | ±0.05 (small steps); ±0.1 (large steps) using focal power mode |
Connector: | HR10A-7R-6PB |
Magnification, distortion and telecentricity specified at 0 dpt. The F# specified is the real working f-number. DOF calculated for 3.45 μm pixels. However, for a very sharp image, only half of the DOF should be considered.